Home / Products / Surge arresters
Eaton Cooper Power Series

Distribution and station surge arresters

IEEE C62.11CFE VA41010 kA
Also known as:lightning arresterUltraSILVariSTARelbow arrester
Surge arresters

What is it and when is it used?

The surge arrester diverts lightning and switching surges to ground before they damage the transformer or substation equipment. It is the lowest-cost protection with the biggest impact on transformer life.

We carry the Eaton Cooper Power Series polymer UltraSIL 10 kA distribution class: Evolution (URT), VariSTAR Heavy-Duty (UHS) and under-oil VariSTAR (AZU) for in-tank mounting.

UltraSIL Evolution (URT)

3 to 36 kV · 10 kA

The top of the distribution line: also suited for riser pole and demanding applications.

VariSTAR Heavy-Duty (UHS)

3 to 36 kV · 10 kA

The polymer workhorse for transformer and line protection.

Under-oil VariSTAR (AZU)

10 to 27 kV

Mounts inside the padmount or submersible transformer tank: protection with no environmental exposure.

Part numbers

Part numberLineClassMCOV
AD150NA100Under-oil arrester disconnector35 kVGet a quote
URT09056P1T4A1EEvolution 10 kA9 kV7.65 kVGet a quote
URT10050A1A1D1AEvolution 10 kA10 kV8.4 kVGet a quote
URT10050A1C1C1AEvolution 10 kA10 kV8.4 kVGet a quote
URT10053D1U1N1AEvolution 10 kA10 kV8.4 kVGet a quote
URT10070A1A1A1AEvolution 10 kA10 kV8.4 kVGet a quote
URT10070A1C1C1AEvolution 10 kA10 kV8.4 kVGet a quote
URT12076P1T1A1EEvolution 10 kA12 kV10.2 kVGet a quote
URT12076P1T1C1EEvolution 10 kA12 kV10.2 kVGet a quote
URT12096P1T1C1AEvolution 10 kA12 kV10.2 kVGet a quote
URT15070A1A1A1AEvolution 10 kA15 kV12.7 kVGet a quote
URT18080A1C1C1AEvolution 10 kA18 kV15.3 kVGet a quote
ASZH480C201Storm Trapper secondary, 2-pole480 V400 VGet a quote
ASZH650C201Storm Trapper secondary, 2-pole650 V540 VGet a quote
AZU100L010VariSTAR under-oil10 kV8.4 kVGet a quote
AZU100L012VariSTAR under-oil12 kV10.2 kVGet a quote
AZU100L027VariSTAR under-oil27 kV22.0 kVGet a quote
USAA010008A1045A11VariSTAR station class10 kV8.4 kVGet a quote
USAA060048A2845A11VariSTAR station class60 kV48 kVGet a quote
UHS03030A1C1C1AVariSTAR Heavy-Duty3 kV2.55 kVGet a quote
UHS10050A1C1C1CVariSTAR Heavy-Duty10 kV8.4 kVGet a quote
UHS18080A1C1C1CVariSTAR Heavy-Duty18 kV15.3 kVGet a quote
UHS27116P1T1A1EVariSTAR Heavy-Duty27 kV22.0 kVGet a quote
URS27120A1C1C1AVariSTAR riser pole27 kV22.0 kVGet a quote

24 part numbers in this family, sorted by type and class. Use the column filters or the search box to narrow down. Click a part number to view its details.

Standards: IEEE C62.11, IEC 60099-4; meets CFE requirements.

Need a quote for surge arresters?

Send us your part number or tell us what you need. Our technical team will assist you directly.

or write to us from the contact section →